s

Home>Drain water > Ultrafiltration membrane > Hollow fiber ultrafiltration membrane >

Hollow fiber ultrafiltration membrane

2015-09-15 11:31:24
Ⅰ.Membrane component size and structure
Model No. Pipe dia(mm) L1(mm) L2(mm) L3(mm) L4(mm) L5(mm)
UF225 (2680) 225mm 1860 1630 95 135 180
UF225 (2880) 225mm 2360 2130 95 135 180
Ⅱ. Component Parameters
Model No. Membrane material Membrane wire specifications Membrane area Retain molecular weight Operation mode Membrane  component specifications
UFf225 (2680) PVC 1.0mm/1.8mm 40m2 100000 Dalton Internal pressure Ф225×1860mm
UFc225 (2680) PVDF 0.8mm/1.3mm 52m2 200000 Dalton External pressure Ф225×1860mm
UFf225 (2880) PVC 1.0mm/1.8mm 54m2 100000 Dalton Internal pressure Ф225×2360mm
UFc225 (2880) PVDF 0.8mm/1.3mm 70m2 200000 Dalton External pressure Ф225×2360mm
Ⅲ. Operation condition
PH range 2-11(when cleanign 2-12)
Max influent turbidity 50NTU
Max influent pressure 0.3MPa
Ultrafiltration normal operating pressure <0.2MPa
Max membrane pressure difference 0.2MPa
Resistance temperature range 5-45℃
Instantaneous maximum residual chlorine concentration 100ppm(less than 10 minutes)
Operation mode  full amount/cross-flow filtration
Ⅳ.Recommended design flux
Influent condition Water saturating rate(L/m2.h) Backwashing frequency
(min)
Maintenance Cleaning
Water type Terbidity NTU TOC(mg/L)
Underground water <2 <1 80 60 Optional
Tap water <3 <2 75 60 Optional
Surface water <2-5 <2 75 60 Optional
<5-15 <5 60 45 Optional
<15-50 <10 50 30 Recommended
Seawater <20 / 60 30 Optional
Advanced treatment
waste water
0-5 <40 35-40 30 Recommended
 
Products
Contact Us

Address:Room 408,No. 8, building 1,Jiaomenbei Road, Fengtai District, Beijing City
TEL:010-59798968
13910221601
FAX:010-59798968-604
WEB:www.bjbluewater.com